SW Protection Logic of Motor
2023-11-27 16:42:31   6  举报             
     
         
 AI智能生成
  SW Protection Logic of Motor
    作者其他创作
 大纲/内容
  Vacuum Fan Motor Protection Logic    
      ADC and real current  
     Designed Parameter and Vacuum degree    
     Quiet Mode: PWM = 8%, Vacuum Degree = 600Pa  
     Standard Mode: PWM = 16%, Vacuum Degree = 1000Pa  
     Medium Mode: PWM = 40%, Vacuum Degree = 2000 Pa  
     Strong Mode: PWM = 89%, Vacuum Degree > 4000 Pa  
     The Logic of decrease the PWM automatically    
     Strong Mode    
     Battery Level >= 80%, PWM 89%, Vacuum Degree > 4000 Pa  
     Battery Level >= 70%, 63% <= PWM <= 86%, the PWM will reduce 1% per 1 minute   
     Battery Level >= 60%, 63% <= PWM <= 80%, the PWM will reduce 1% per 1 minute  
     Battery Level >= 50%, 63% <= PWM <= 77%, the PWM will reduce 1% per 1 minute  
     Battery Level >= 40%, 63% <= PWM <= 71%, the PWM will reduce 1% per 1 minute  
     Battery Level >= 30%, 63% <= PWM <= 68%, the PWM will reduce 1% per 1 minute  
     Battery Level < 30%, PWM = 63%  
     Medium Mode    
     Battery Level >= 80%, PWM 40%, Vacuum Degree  2000 Pa  
     Battery Level >= 70%, 29% <= PWM <= 38%, the PWM will reduce 1% per 10 minutes  
     Battery Level >= 60%, 29% <= PWM <= 36%, the PWM will reduce 1% per 10 minutes  
     Battery Level >= 50%, 29% <= PWM <= 34%, the PWM will reduce 1% per 10 minutes  
     Battery Level >= 40%, 29% <= PWM <= 32%, the PWM will reduce 1% per 10 minutes  
     Battery Level >= 30%, 29% <= PWM <= 30%, the PWM will reduce 1% per 10 minutes  
     Battery Level < 30%, PWM = 29%  
     Main Brush Motor Protection Logic    
     ADC and real current  
     Designed Parameter    
     PWM = 65%, Rotation Speed = 1100rpm  
     The Logic of Protection based on current    
     Detect 90s, if 0.42A <= current <= 0.6A in 70% of 90s, go into slight protection mode     
     The main brush moto stop 2min then start again  
     Detect 30s, if 0.6A <= current <= 1.2A in 70% of 30s, go into mid protection mode    
     The main brush moto stop 2min then start again  
     Detect 5.2s, if 1.2A <= current <= 1.6A in 70% of 5.2s, go into strong protection mode    
     1st go into this protection mode, the main brush stop 5s
If not trigger this protection mode in 15s, recover count to 0 and the logic of the first time go into this protection mode
else count +1
    If not trigger this protection mode in 15s, recover count to 0 and the logic of the first time go into this protection mode
else count +1
 2nd go into this protection mode, the main brush stop 10s
If not trigger this protection mode in 25s, recover count to 0 and the logic of the first time go into this protection mode
else count +1
  
    If not trigger this protection mode in 25s, recover count to 0 and the logic of the first time go into this protection mode
else count +1
 3rd go into this protection mode, the main brush stop 1mrin
If not trigger this protection mode in 125s, recover count to 0 and the logic of the first time go into this protection mode
else count +1
    If not trigger this protection mode in 125s, recover count to 0 and the logic of the first time go into this protection mode
else count +1
 4th go into this protection mode, the main brush stop 5min
If not trigger this protection mode in 10min+5s, recover count to 0 and the logic of the first time go into this protection mode
else count +1
    If not trigger this protection mode in 10min+5s, recover count to 0 and the logic of the first time go into this protection mode
else count +1
 Detect 2.2s, if 1.6A <= current in 90% of 2.2s, go into disaster protection mode    
     1st go into this protection mode, the main brush stop 5s
If not trigger this protection mode in 15s, recover count to 0 and the logic of the first time go into this protection mode
else count +1
    If not trigger this protection mode in 15s, recover count to 0 and the logic of the first time go into this protection mode
else count +1
 2nd go into this protection mode, the main brush stop 10s
If not trigger this protection mode in 25s, recover count to 0 and the logic of the first time go into this protection mode
else count +1
    If not trigger this protection mode in 25s, recover count to 0 and the logic of the first time go into this protection mode
else count +1
 3rd go into this protection mode, the main brush stop 1mrin
If not trigger this protection mode in 125s, recover count to 0 and the logic of the first time go into this protection mode
else count +1
    If not trigger this protection mode in 125s, recover count to 0 and the logic of the first time go into this protection mode
else count +1
 4th go into this protection mode, the main brush stop 5min
If not trigger this protection mode in 10min+5s, recover count to 0 and the logic of the first time go into this protection mode
else count +1
    If not trigger this protection mode in 10min+5s, recover count to 0 and the logic of the first time go into this protection mode
else count +1
 Left and Right Wheel Protection Logic    
     Detect 5 min, if .0.5A <= current <= 0.7A    
     The wheel stop 5s  
     Detect 1min, if 0.7A <= current <= 1A    
     The wheel stop 5s  
     Detect 3s, if 1A < current    
     The wheel stop 5s  
     In a single clean session, if 4 times were detected, the robot will alarm and stop  
     Side Brush Motor Protection Logic    
     0.1A < current    
     The side brush working on 1s and stop 2s  
    
 
 
 
 